Guide Roller

Guide Roller

A Guide Roller is a mechanical guidance assembly installed on the perimeter of an External Floating Roof Tank (EFRT) or Internal Floating Roof Tank (IFRT) to maintain the floating roof in a concentric position within the tank shell during vertical movement. The guide roller minimizes lateral roof movement, reduces friction between the roof and the shell, accommodates shell out-of-roundness, and prevents damage to rim seals, guide poles, roof drains, rolling ladders, and other roof-mounted accessories. The assembly is designed for continuous operation under varying product levels, wind loads, and thermal expansion while ensuring smooth and stable roof travel.

Typical Application

  • External Floating Roof Tanks (EFRTs).
  • Internal Floating Roof Tanks (IFRTs).
  • Crude Oil Storage Tanks.
  • Gasoline, Diesel, Naphtha, ATF, Kerosene, and Petrochemical Storage Tanks.
  • Refineries, Petrochemical Plants, Tank Farms, Marine Terminals, and Bulk Liquid Storage Facilities.
  • New tank construction and retrofit projects where roof guidance and seal protection are required.

Guideline / Standard

Storage Tank Standards

  • API 650 – Welded Tanks for Oil Storage (floating roof design, roof attachments, and accessories).
  • API 653 – Inspection, Repair, Alteration, and Reconstruction of Storage Tanks.

Engineering Practice

  • EEMUA 159 – Guide for the Design, Construction, Modification, Repair, and Inspection of Above Ground Flat Bottomed Storage Tanks.
  • EN 14015 – Specification for the Design and Manufacture of Site-built, Vertical, Cylindrical, Flat-bottomed Steel Tanks.

Safety Standards

  • API RP 545 Rev. 1 – Lightning Protection of Aboveground Storage Tanks (guide roller installation shall not interfere with bonding conductors or lightning protection devices).
  • NFPA 780 – Standard for the Installation of Lightning Protection Systems (where applicable).

Indian Standards

  • OISD-118 – Inspection and Maintenance of Aboveground Petroleum Storage Tanks.
  • OISD-244 – Fire Protection Requirements for Petroleum Installations (general tank safety requirements).

Project Standards

  • Owner specifications (BPCL, HPCL, IOCL, ONGC, ADNOC, Saudi Aramco, Shell, etc.) and EPC/PMC engineering requirements.

Material of Construction (MOC)

Roller Wheel: Stainless Steel SS304/SS316, Cast Stainless Steel, or Carbon Steel with Polyurethane (PU), UHMWPE, or Nylon outer rolling surface depending on service conditions.
Roller Shaft / Axle: Stainless Steel SS304 or SS316.
Roller Bearings: Sealed Stainless Steel Ball Bearings or Heavy-duty Roller Bearings (maintenance-free type preferred).
Support Bracket: Carbon Steel (ASTM A36 / IS 2062) with Hot-Dip Galvanizing or Epoxy Coating, or Stainless Steel SS304/SS316 for corrosive environments.
Spacer Bushes: PTFE, UHMWPE, Nylon, or Oil-impregnated Bronze.
Fasteners: Stainless Steel SS304 or SS316 (A2-70/A4-80).
Protective Coating (Carbon Steel): Zinc-rich primer with Epoxy Intermediate Coat and Polyurethane Top Coat or Hot-Dip Galvanizing (minimum project-specified coating thickness).