Welcome to Agasti Tank Works Pvt Ltd marketing@agasticorporation.com
Certified Company
ISO 14001 :2015
Certified Company
ISO 45001 :2018
Certified Company
ISO 9001 :2015
Call Us
+91-9579868575

Aluminium Internal Floating Roof (AIFR)

Aluminium Internal Floating Roof (AIFR)

An Aluminum Internal Floating Roof (IFR) is a lightweight, non-contact floating deck installed inside a fixed roof storage tank to float directly on the surface of stored petroleum products. It significantly reduces evaporative losses (VOC emissions), minimizes product contamination, limits oxygen ingress, improves fire safety by reducing vapour space, and enhances environmental compliance. Aluminum IFRs typically consist of interlocking aluminum panels or full-contact honeycomb deck modules supported by sealed aluminum pontoons, with peripheral rim seals, support legs, vents, gauge well boots, rolling ladder interfaces, and other accessories. The roof is designed to provide excellent buoyancy, corrosion resistance, low maintenance, and long service life while maintaining operational safety.

 

Typical Application

  • Fixed Roof Storage Tanks fitted with Internal Floating Roofs.
  • Crude Oil Storage Tanks.
  • Gasoline, Diesel, Naphtha, Jet Fuel (ATF), Kerosene, Ethanol, Benzene, Toluene, Xylene and other volatile hydrocarbon products.
  • Petrochemical and Chemical Storage Tanks.
  • Refineries and Petrochemical Plants.
  • Oil Terminals and Bulk Liquid Storage Facilities.
  • Aviation Fuel Depots.
  • New tank construction and retrofit applications for emission control and product conservation.

Guideline / Standard

Storage Tank Standards

  • API 650 – Welded Tanks for Oil Storage (Appendix H – Internal Floating Roofs).
  • API 653 – Inspection, Repair, Alteration, and Reconstruction of Storage Tanks.

Venting & Vapor Control

  • API 2000 – Venting Atmospheric and Low-pressure Storage Tanks.
  • API 2003 – Protection Against Ignitions Arising Out of Static, Lightning and Stray Currents.

Lightning Protection

  • API RP 545 Rev.1 – Lightning Protection of Aboveground Storage Tanks.
  • NFPA 780 – Standard for the Installation of Lightning Protection Systems.

Fire & Environmental Standards

  • NFPA 30 – Flammable and Combustible Liquids Code.
  • Applicable local environmental regulations for VOC emission control.

International Standards

  • EN 14015 – Design and Manufacture of Site-built Vertical Cylindrical Steel Tanks.
  • EEMUA 159 – Aboveground Flat-bottomed Storage Tanks.

Indian Standards

  • OISD-118 – Inspection and Maintenance of Aboveground Petroleum Storage Tanks.
  • OISD-244 – Fire Protection Requirements for Petroleum Installations.
  • Owner specifications (BPCL, HPCL, IOCL, ONGC, ADNOC, Saudi Aramco, Shell, etc.) where applicable.

Material of Construction (MOC)

Deck Panels: Marine-grade Aluminium Alloy AA 5052-H32, AA 5052-H34, AA 3003-H14, or AA 6061-T6, depending on design requirements.
Pontoon Tubes: Aluminium Alloy AA 6063-T5, AA 6061-T6, or AA 5052-H32.
Structural Beams & Trusses: Extruded Aluminium Alloy AA 6061-T6 or AA 6063-T6.
Rim Seal: Primary and/or Secondary Seal with stainless steel hardware and fuel-resistant elastomeric or reinforced polymer seal fabric (NBR, PU, Viton, PTFE-coated fabric, etc.).
Support Legs: Aluminium Alloy or Hot-Dip Galvanized Carbon Steel with Stainless Steel adjustment hardware.
Fasteners: Stainless Steel SS304 or SS316 (A2-70/A4-80).
Guide Rollers / Wear Pads: UHMWPE, PTFE, Nylon, or other engineering polymers with stainless steel shafts.
Gauge Well Boots: Fuel-resistant reinforced elastomer (NBR, Viton, PTFE composite, or equivalent).
Drainage & Vent Components: Aluminium Alloy with Stainless Steel hardware.
Bonding Cables / Shunts: Tinned Copper or Stainless Steel braided conductors where required by API RP 545.

 

Related Products

High-Performance System

Our Liquid Mounted Primary Foam Seal provides reliable vapour sealing, reduces product loss, and enhances the safety and efficiency of floating roof storage tanks.

X
0%